FDA 8CH
OHWR0069 · revision R1
FDA 8CH (OHWR0069 R1) is an open-hardware circuit board from the CERN Open Hardware Repository, designed in KiCad EDA: a 2-layer board of 170 × 70 mm with 416 components and 134 nets, published under CERN-OHL-1.2.
review 92% walked · 9 findings: 1 blocker · 5 major · 3 minor (19 items)
Open in the interactive viewerRead the full review

Design review
Probe recorded 9 findings: 1 blocker · 5 major · 3 minor (19 items) on this design. Each is shown here with its reasoning; the full review links every one to the pins, nets and datasheet pages it rests on.
- PowerRailConflictblockerOpen
P901 bridges different-voltage rails: Vin_POS (9V), Vin_NEG (-9V)
P901 (3-pin part) bridges different-voltage rails: Vin_POS (9V), Vin_NEG (-9V) — rail-to-rail short?
At P901
- CapVoltageDeratingmajorOpen
C906 sits on a 8.5 V rail and its voltage rating is not in the BOM
C906: on a 8.5 V rail but its voltage rating is not stated in the BOM — add it so the rating can be compared to the rail at all. No datasheet is on file for this part; the BOM short-spec is the source.
At C906
- CapVoltageDeratingmajorOpen
C908 sits on a 8.5 V rail and its voltage rating is not in the BOM
C908: on a 8.5 V rail but its voltage rating is not stated in the BOM — add it so the rating can be compared to the rail at all. No datasheet is on file for this part; the BOM short-spec is the source.
At C908
- CapVoltageDeratingmajorOpen
CapVoltageDerating: 2 components×2
e.g. “C905 sits on a 9 V rail and its voltage rating is not in the BOM”
At C905, C907
Each finding, with its own headline
C905C905 sits on a 9 V rail and its voltage rating is not in the BOM
C905: on a 9 V rail but its voltage rating is not stated in the BOM — add it so the rating can be compared to the rail at all. No datasheet is on file for this part; the BOM short-spec is the source. 'Net-(C905-Pad1)' sits at -9 V; a voltage rating is a magnitude, so it is judged at 9 V.
C907C907 sits on a 9 V rail and its voltage rating is not in the BOM
C907: on a 9 V rail but its voltage rating is not stated in the BOM — add it so the rating can be compared to the rail at all. No datasheet is on file for this part; the BOM short-spec is the source. 'LDO_IN_NEG' sits at -9 V; a voltage rating is a magnitude, so it is judged at 9 V.
- ReferencePlaneDiscontinuitymajorOpen
ReferencePlaneDiscontinuity: 10 boards×10
Checked by the review, stands · Claude walker W1 (Cern session) — Checked: the GND-pour cut-backs (1.02 mm, one per channel input) and routed crossings read from the copper stand. They sit on the channel input coupling nets; no datasheet or app note on file sets a limit, and the crossings are millimetre-scale against the amplifier band. Left for the owner.
At void:GND@B.CU:103,-73.2, void:GND@B.CU:119,-73.2, void:GND@B.CU:135,-73.2, void:GND@B.CU:151,-73.2, void:GND@B.CU:167,-73.2, void:GND@B.CU:183,-73.2 and 4 more
Each finding, with its own headline
void:GND@B.CU:103,-73.2'Net-(C301-Pad2)' crosses where the outline of the GND plane on B.CU is drawn back, at 1 place, the longest 1.02 mm (fastest: Net-(C301-Pad2) at 100 ps 10-90 %, ASSUMED)
Along 'Net-(C301-Pad2)' on F.CU, the GND plane on B.CU has 1.02 mm under the track with no copper, at (103, -73.2), the same plane on both sides. No single drill's anti-pad and no landing explains it: a clearance is excused only when it holds a drill and is drawn round it, or the track ends in it on the net's own pad or via, or runs through its own via's clearance and no farther. The return current detours round the void. No hole cleared it: the outline of the pour at x 50.05..219.95, y -132.95..-63.05 is drawn back there. One decision covers the void: whether these tracks may cross it, or the plane should be filled under them. No crossing has a plane on the track's other side, so the whole return meets the break.
- 'Net-(C301-Pad2)' on F.CU at (103, -73.2), 1.02 mm over no copper; other side: none: the signal layer is outermost
Every site is a row of this finding's evidence, keyed by net, layers and position. GET /api/odb/boards/70/reference-planes?group=void%3AGND%40B.CU%3A103%2C-73.2 serves each with its own layer_image region; all of them lie in x 102..104, y -77.46..-71.94 mm (board frame, Y up).
Read from the copper as drawn on the reference layer, along each track's centreline at exact breakpoints. The reference is the copper beside the track, never the layer's type or name. Whether it matters depends on each signal's edge rate, which nothing on file states for these nets: a slow static line crosses a split harmlessly, a fast edge does not.
void:GND@B.CU:119,-73.2'Net-(C401-Pad2)' crosses where the outline of the GND plane on B.CU is drawn back, at 1 place, the longest 1.02 mm (fastest: Net-(C401-Pad2) at 100 ps 10-90 %, ASSUMED)
Along 'Net-(C401-Pad2)' on F.CU, the GND plane on B.CU has 1.02 mm under the track with no copper, at (119, -73.2), the same plane on both sides. No single drill's anti-pad and no landing explains it: a clearance is excused only when it holds a drill and is drawn round it, or the track ends in it on the net's own pad or via, or runs through its own via's clearance and no farther. The return current detours round the void. No hole cleared it: the outline of the pour at x 50.05..219.95, y -132.95..-63.05 is drawn back there. One decision covers the void: whether these tracks may cross it, or the plane should be filled under them. No crossing has a plane on the track's other side, so the whole return meets the break.
- 'Net-(C401-Pad2)' on F.CU at (119, -73.2), 1.02 mm over no copper; other side: none: the signal layer is outermost
Every site is a row of this finding's evidence, keyed by net, layers and position. GET /api/odb/boards/70/reference-planes?group=void%3AGND%40B.CU%3A119%2C-73.2 serves each with its own layer_image region; all of them lie in x 118..120, y -77.46..-71.94 mm (board frame, Y up).
Read from the copper as drawn on the reference layer, along each track's centreline at exact breakpoints. The reference is the copper beside the track, never the layer's type or name. Whether it matters depends on each signal's edge rate, which nothing on file states for these nets: a slow static line crosses a split harmlessly, a fast edge does not.
void:GND@B.CU:135,-73.2'Net-(C501-Pad2)' crosses where the outline of the GND plane on B.CU is drawn back, at 1 place, the longest 1.02 mm (fastest: Net-(C501-Pad2) at 100 ps 10-90 %, ASSUMED)
Along 'Net-(C501-Pad2)' on F.CU, the GND plane on B.CU has 1.02 mm under the track with no copper, at (135, -73.2), the same plane on both sides. No single drill's anti-pad and no landing explains it: a clearance is excused only when it holds a drill and is drawn round it, or the track ends in it on the net's own pad or via, or runs through its own via's clearance and no farther. The return current detours round the void. No hole cleared it: the outline of the pour at x 50.05..219.95, y -132.95..-63.05 is drawn back there. One decision covers the void: whether these tracks may cross it, or the plane should be filled under them. No crossing has a plane on the track's other side, so the whole return meets the break.
- 'Net-(C501-Pad2)' on F.CU at (135, -73.2), 1.02 mm over no copper; other side: none: the signal layer is outermost
Every site is a row of this finding's evidence, keyed by net, layers and position. GET /api/odb/boards/70/reference-planes?group=void%3AGND%40B.CU%3A135%2C-73.2 serves each with its own layer_image region; all of them lie in x 134..136, y -77.46..-71.94 mm (board frame, Y up).
Read from the copper as drawn on the reference layer, along each track's centreline at exact breakpoints. The reference is the copper beside the track, never the layer's type or name. Whether it matters depends on each signal's edge rate, which nothing on file states for these nets: a slow static line crosses a split harmlessly, a fast edge does not.
void:GND@B.CU:151,-73.2'Net-(C601-Pad2)' crosses where the outline of the GND plane on B.CU is drawn back, at 1 place, the longest 1.02 mm (fastest: Net-(C601-Pad2) at 100 ps 10-90 %, ASSUMED)
Along 'Net-(C601-Pad2)' on F.CU, the GND plane on B.CU has 1.02 mm under the track with no copper, at (151, -73.2), the same plane on both sides. No single drill's anti-pad and no landing explains it: a clearance is excused only when it holds a drill and is drawn round it, or the track ends in it on the net's own pad or via, or runs through its own via's clearance and no farther. The return current detours round the void. No hole cleared it: the outline of the pour at x 50.05..219.95, y -132.95..-63.05 is drawn back there. One decision covers the void: whether these tracks may cross it, or the plane should be filled under them. No crossing has a plane on the track's other side, so the whole return meets the break.
- 'Net-(C601-Pad2)' on F.CU at (151, -73.2), 1.02 mm over no copper; other side: none: the signal layer is outermost
Every site is a row of this finding's evidence, keyed by net, layers and position. GET /api/odb/boards/70/reference-planes?group=void%3AGND%40B.CU%3A151%2C-73.2 serves each with its own layer_image region; all of them lie in x 150..152, y -77.46..-71.94 mm (board frame, Y up).
Read from the copper as drawn on the reference layer, along each track's centreline at exact breakpoints. The reference is the copper beside the track, never the layer's type or name. Whether it matters depends on each signal's edge rate, which nothing on file states for these nets: a slow static line crosses a split harmlessly, a fast edge does not.
void:GND@B.CU:167,-73.2'Net-(C701-Pad2)' crosses where the outline of the GND plane on B.CU is drawn back, at 1 place, the longest 1.02 mm (fastest: Net-(C701-Pad2) at 100 ps 10-90 %, ASSUMED)
Along 'Net-(C701-Pad2)' on F.CU, the GND plane on B.CU has 1.02 mm under the track with no copper, at (167, -73.2), the same plane on both sides. No single drill's anti-pad and no landing explains it: a clearance is excused only when it holds a drill and is drawn round it, or the track ends in it on the net's own pad or via, or runs through its own via's clearance and no farther. The return current detours round the void. No hole cleared it: the outline of the pour at x 50.05..219.95, y -132.95..-63.05 is drawn back there. One decision covers the void: whether these tracks may cross it, or the plane should be filled under them. No crossing has a plane on the track's other side, so the whole return meets the break.
- 'Net-(C701-Pad2)' on F.CU at (167, -73.2), 1.02 mm over no copper; other side: none: the signal layer is outermost
Every site is a row of this finding's evidence, keyed by net, layers and position. GET /api/odb/boards/70/reference-planes?group=void%3AGND%40B.CU%3A167%2C-73.2 serves each with its own layer_image region; all of them lie in x 166..168, y -77.46..-71.94 mm (board frame, Y up).
Read from the copper as drawn on the reference layer, along each track's centreline at exact breakpoints. The reference is the copper beside the track, never the layer's type or name. Whether it matters depends on each signal's edge rate, which nothing on file states for these nets: a slow static line crosses a split harmlessly, a fast edge does not.
void:GND@B.CU:183,-73.2'Net-(C801-Pad2)' crosses where the outline of the GND plane on B.CU is drawn back, at 1 place, the longest 1.02 mm (fastest: Net-(C801-Pad2) at 100 ps 10-90 %, ASSUMED)
Along 'Net-(C801-Pad2)' on F.CU, the GND plane on B.CU has 1.02 mm under the track with no copper, at (183, -73.2), the same plane on both sides. No single drill's anti-pad and no landing explains it: a clearance is excused only when it holds a drill and is drawn round it, or the track ends in it on the net's own pad or via, or runs through its own via's clearance and no farther. The return current detours round the void. No hole cleared it: the outline of the pour at x 50.05..219.95, y -132.95..-63.05 is drawn back there. One decision covers the void: whether these tracks may cross it, or the plane should be filled under them. No crossing has a plane on the track's other side, so the whole return meets the break.
- 'Net-(C801-Pad2)' on F.CU at (183, -73.2), 1.02 mm over no copper; other side: none: the signal layer is outermost
Every site is a row of this finding's evidence, keyed by net, layers and position. GET /api/odb/boards/70/reference-planes?group=void%3AGND%40B.CU%3A183%2C-73.2 serves each with its own layer_image region; all of them lie in x 182..184, y -77.46..-71.94 mm (board frame, Y up).
Read from the copper as drawn on the reference layer, along each track's centreline at exact breakpoints. The reference is the copper beside the track, never the layer's type or name. Whether it matters depends on each signal's edge rate, which nothing on file states for these nets: a slow static line crosses a split harmlessly, a fast edge does not.
void:GND@B.CU:199,-73.2'Net-(C1001-Pad2)' crosses where the outline of the GND plane on B.CU is drawn back, at 1 place, the longest 1.02 mm (fastest: Net-(C1001-Pad2) at 100 ps 10-90 %, ASSUMED)
Along 'Net-(C1001-Pad2)' on F.CU, the GND plane on B.CU has 1.02 mm under the track with no copper, at (199, -73.2), the same plane on both sides. No single drill's anti-pad and no landing explains it: a clearance is excused only when it holds a drill and is drawn round it, or the track ends in it on the net's own pad or via, or runs through its own via's clearance and no farther. The return current detours round the void. No hole cleared it: the outline of the pour at x 50.05..219.95, y -132.95..-63.05 is drawn back there. One decision covers the void: whether these tracks may cross it, or the plane should be filled under them. No crossing has a plane on the track's other side, so the whole return meets the break.
- 'Net-(C1001-Pad2)' on F.CU at (199, -73.2), 1.02 mm over no copper; other side: none: the signal layer is outermost
Every site is a row of this finding's evidence, keyed by net, layers and position. GET /api/odb/boards/70/reference-planes?group=void%3AGND%40B.CU%3A199%2C-73.2 serves each with its own layer_image region; all of them lie in x 198..200, y -77.46..-71.94 mm (board frame, Y up).
Read from the copper as drawn on the reference layer, along each track's centreline at exact breakpoints. The reference is the copper beside the track, never the layer's type or name. Whether it matters depends on each signal's edge rate, which nothing on file states for these nets: a slow static line crosses a split harmlessly, a fast edge does not.
void:GND@B.CU:71,-73.2'Net-(C101-Pad2)' crosses where the outline of the GND plane on B.CU is drawn back, at 1 place, the longest 1.02 mm (fastest: Net-(C101-Pad2) at 100 ps 10-90 %, ASSUMED)
Along 'Net-(C101-Pad2)' on F.CU, the GND plane on B.CU has 1.02 mm under the track with no copper, at (71, -73.2), the same plane on both sides. No single drill's anti-pad and no landing explains it: a clearance is excused only when it holds a drill and is drawn round it, or the track ends in it on the net's own pad or via, or runs through its own via's clearance and no farther. The return current detours round the void. No hole cleared it: the outline of the pour at x 50.05..219.95, y -132.95..-63.05 is drawn back there. One decision covers the void: whether these tracks may cross it, or the plane should be filled under them. No crossing has a plane on the track's other side, so the whole return meets the break.
- 'Net-(C101-Pad2)' on F.CU at (71, -73.2), 1.02 mm over no copper; other side: none: the signal layer is outermost
Every site is a row of this finding's evidence, keyed by net, layers and position. GET /api/odb/boards/70/reference-planes?group=void%3AGND%40B.CU%3A71%2C-73.2 serves each with its own layer_image region; all of them lie in x 70..72, y -77.46..-71.94 mm (board frame, Y up).
Read from the copper as drawn on the reference layer, along each track's centreline at exact breakpoints. The reference is the copper beside the track, never the layer's type or name. Whether it matters depends on each signal's edge rate, which nothing on file states for these nets: a slow static line crosses a split harmlessly, a fast edge does not.
void:GND@B.CU:87,-73.2'Net-(C201-Pad2)' crosses where the outline of the GND plane on B.CU is drawn back, at 1 place, the longest 1.02 mm (fastest: Net-(C201-Pad2) at 100 ps 10-90 %, ASSUMED)
Along 'Net-(C201-Pad2)' on F.CU, the GND plane on B.CU has 1.02 mm under the track with no copper, at (87, -73.2), the same plane on both sides. No single drill's anti-pad and no landing explains it: a clearance is excused only when it holds a drill and is drawn round it, or the track ends in it on the net's own pad or via, or runs through its own via's clearance and no farther. The return current detours round the void. No hole cleared it: the outline of the pour at x 50.05..219.95, y -132.95..-63.05 is drawn back there. One decision covers the void: whether these tracks may cross it, or the plane should be filled under them. No crossing has a plane on the track's other side, so the whole return meets the break.
- 'Net-(C201-Pad2)' on F.CU at (87, -73.2), 1.02 mm over no copper; other side: none: the signal layer is outermost
Every site is a row of this finding's evidence, keyed by net, layers and position. GET /api/odb/boards/70/reference-planes?group=void%3AGND%40B.CU%3A87%2C-73.2 serves each with its own layer_image region; all of them lie in x 86..88, y -77.46..-71.94 mm (board frame, Y up).
Read from the copper as drawn on the reference layer, along each track's centreline at exact breakpoints. The reference is the copper beside the track, never the layer's type or name. Whether it matters depends on each signal's edge rate, which nothing on file states for these nets: a slow static line crosses a split harmlessly, a fast edge does not.
void:routed@B.CU|F.CU3 nets on F.CU cross the tracks routed through the GND pour on B.CU at 17 places, the longest 1.89 mm (fastest: /out1/Input at 100 ps 10-90 %, ASSUMED)
The GND pour on B.CU is cleared round tracks routed through it, and tracks on F.CU, which take that pour as their reference, cross them: for the width of each cut the return has no plane under it and detours round the cut. 17 place(s) on 3 net(s). One decision covers the layer pair: whether these layers may take a pour their own tracks cut as the reference, or the routing or the stackup should give the tracks a plane that is not cut where they cross. No crossing has a plane on the track's other side, so the whole return meets the break.
- 'Net-(R901-Pad2)' on F.CU at (77.43, -119.57), 1.89 mm over copper of +6V, not a plane; other side: none: the signal layer is outermost
- '/out1/Input' on F.CU at (108.57, -102), 1.36 mm over copper of -6V, not a plane; other side: none: the signal layer is outermost
- '/out1/Input' on F.CU at (111.43, -102), 1.36 mm over copper of +6V, not a plane; other side: none: the signal layer is outermost
- '/out1/Input' on F.CU at (124.57, -102), 1.36 mm over copper of -6V, not a plane; other side: none: the signal layer is outermost
- '/out1/Input' on F.CU at (127.43, -102), 1.36 mm over copper of +6V, not a plane; other side: none: the signal layer is outermost
- '/out1/Input' on F.CU at (140.57, -102), 1.36 mm over copper of -6V, not a plane; other side: none: the signal layer is outermost
- '/out1/Input' on F.CU at (142.57, -102), 1.36 mm over copper of +6V, not a plane; other side: none: the signal layer is outermost
- '/out1/Input' on F.CU at (156.57, -102), 1.36 mm over copper of -6V, not a plane; other side: none: the signal layer is outermost
- '/out1/Input' on F.CU at (158.57, -102), 1.36 mm over copper of +6V, not a plane; other side: none: the signal layer is outermost
- '/out1/Input' on F.CU at (172.57, -102), 1.36 mm over copper of -6V, not a plane; other side: none: the signal layer is outermost
- '/out1/Input' on F.CU at (174.57, -102), 1.36 mm over copper of +6V, not a plane; other side: none: the signal layer is outermost
- '/out1/Input' on F.CU at (188.57, -102), 1.36 mm over copper of -6V, not a plane; other side: none: the signal layer is outermost
- and 5 more
Every site is a row of this finding's evidence, keyed by net, layers and position. GET /api/odb/boards/70/reference-planes?group=void%3Arouted%40B.CU%7CF.CU serves each with its own layer_image region; all of them lie in x 75.32..196.18, y -126.7..-101 mm (board frame, Y up).
Read from the copper as drawn on the reference layer, along each track's centreline at exact breakpoints. The reference is the copper beside the track, never the layer's type or name. Whether it matters depends on each signal's edge rate, which nothing on file states for these nets: a slow static line crosses a split harmlessly, a fast edge does not.
- FiducialMissingmajorOpen
The top side carries 193 SMT component(s) and no fiducial was found on it
The top side carries 193 SMT component(s) but no fiducial was found on it — a placement machine has no optical reference to align to. Probe found no pad labelled .pad_usage=g_fiducial/l_fiducial (basis pad_usage); no single-pad, netless, undrilled component whose 0.5-3 mm round pad has a concentric solder-mask opening at least 1.5x its diameter with no other copper inside it (basis geometry); and no component whose refdes starts FID or whose part or package name contains FIDUCIAL (basis footprint-name). If your library names fiducials something Probe does not recognise, mark this benign — disposition_finding(rule='FiducialMissing', entity='top', status='benign', reason=…) — the name match only ever silences this check, it never asserts anything. If the side really has no fiducial, say so with status='confirmed': that answers the finding and keeps it gating release.
At top
Coax connector values disagree with their footprints on all nine input/output pairs
On all nine coax input/output pairs, the connector value disagrees with its footprint: parts valued SMA sit on BNC or SMB footprints and parts valued BNC on SMB footprints, so the BOM names a connector that does not match its land pattern.
Refdes Value Order code Footprint Source J201 (and J301-J1001) CONN_COAXIAL_SMA Farnell 2293854 awallinKiCadFootprints:BNC_2PIN netlist; output stage sheet J202 (and J302-J1002) CONN_COAXIAL_BNC Farnell 1076295 Connect:SMB_Straight netlist; output stage sheet J101 BNC BNC_2PIN, consistent netlist J102 SMA Connect:SMB_Straight netlist The input pair repeats the pattern: J101 is consistent, J102 is not.
C901-C904 are listed as fitted 10u in the BOM but the PSU sheet says they are not installed
C901-C904 are listed as fitted 10u in the BOM, but the PSU sheet says they are not installed.
Source What it says Sheet 2 (FDA_PSU.kicad_sch) title-block comment "not installed. C901, C902, C903, C904"; the symbols carry value 10u PCB and designer BOM all four as 10u, 0805, no do-not-fit marking Output-stage resistor designators overlap on the top silkscreen
Output-stage designators overlap on the top silkscreen, for example R203 over R204 beside U201, so these parts cannot be identified from the board.
The designators of neighbouring 0805 parts are printed on top of each other:
- R203 and R204, beside U201
- C605 and R603, and R508 and R504, in the other stages (from the overview)
Main parts
| Part number | Maker | Description | Where |
|---|---|---|---|
| LMH6702 | U101 | ||
| LT1963A | U1 | ||
| LT3015 | U2 | ||
| BNX025 | FL901, FL902 | ||
| LMH6609 | U1001, U201, U301, U401, U501, U601, U701, U801 |
About this design
- Design
- FDA 8CH — OHWR0069 R1
- Designed in
- KiCad EDA
- Board
- 2 copper layers, 170 × 70 mm, 416 components, 134 nets
- Licence
- CERN-OHL-1.2
- Source
- https://gitlab.com/ohwr/project/pda-8ch-fda-8ch at commit
911c25f444c6 - Attribution
- CERN Open Hardware Repository, project ohwr/project/pda-8ch-fda-8ch (commit 911c25f444c6630dac731f8eacf6c6b89fd4a4c7, 2025-04-09). Licence: CERN-OHL-1.2. Source: https://gitlab.com/ohwr/project/pda-8ch-fda-8ch. This is a snapshot of the copy published on the OHWR GitLab pages (R1), not CERN's released record. CERN's source of truth is EDMS (https://edms.cern.ch), and the current release may be newer.
- Reviewed with
- Probe by E# (E-Sharp AB)